ADSS Fiber Optic Cable 600 SPAN B1.3 PE
.png)
Price: Rs 0.00
Fiber Specifications
- Material: Quartz glass (Silicon Dioxide)
- Structure:
- Core: 9 μm (high refractive index)
- Cladding: 125 μm (low refractive index)
- Coating: 245 μm (protective resin)
Parameter | Requirement | Standard (if applicable) |
Core non-circularity | ≤ 6% | ITU-T G.652 |
Cladding diameter | 125.0 ± 0.7 μm | - |
Core/Cladding concentricity | ≤ 0.6 μm | - |
Cladding non-circularity | ≤ 1.0% | - |
Coating diameter | 245 ± 10 μm | - |
Cladding/Coating concentricity | ≤ 12 μm | - |
Attenuation coefficient | 1310 nm: ≤ 0.35 dB/km 1550 nm: ≤ 0.21 dB/km | - |
Zero dispersion slope | ≤ 0.092 ps/(nm²·km) | - |
Zero dispersion wavelength | 1300–1324 nm | - |
Polarization dispersion | ≤ 0.20 ps/√km | - |
Mode field diameter (1310 nm) | 9.0 ± 0.4 μm | - |
Cut-off wavelength | 1170–1330 nm | - |
Chromatic dispersion | 1288–1339 nm: ≤ 3.4 ps/(nm·km) 1550 nm: ≤ 18 ps/(nm·km) 1625 nm: ≤ 22 ps/(nm·km) |
Cable Parameters
Parameter | Value |
Fibers per loose tube | 6 |
Number of tubes | 2 |
Inner sheath thickness | 1.0 mm |
Outer sheath thickness | 1.7 mm |
Aramid area | 2.8 mm² |
Cable diameter | 13 mm (±5%) |
Cable cross-section | 106 mm² |
Cable weight | 105 kg/km (±10%) |
4. Mechanical & Environmental Performance
- Key Parameters:
- RTS (Rated Tensile Strength): 4800 N
- MAT (Maximum Allowable Tension): 1900 N
- Static bending radius: ≥ 174 mm
- Dynamic bending radius: ≥ 290 mm
- Operating temperature: -40°C to +70°C
- Installation temperature: -10°C to +40°C
5. Test Requirements
Test Type | Standard | Key Criteria |
Tensile Test | IEC 60794-1-21-E1 | - RTS: No break at 100% RTS. - UOS (60% RTS): Fiber strain < 0.35%, no added attenuation. - MAT (40% RTS): Strain < 0.05%. |
Crush Test | IEC 60794-1-21-E3 | ≤ 0.1 dB attenuation @1550 nm under 2200 N; no residual attenuation. |
Impact Test | IEC 60794-1-21-E4 | 450g weight, 1m height, 5 impacts. No sheath cracks or residual attenuation. |
Repeated Bending | IEC 60794-1-21-E6 | 30 bends under 150 N load. No cracks/residual attenuation. |
Torsion Test | IEC 60794-1-21-E7 | ±180° twist, 10 cycles. No added attenuation or sheath damage. |
Temperature Cycling | IEC 60794-1-22-F1 | -40°C to +65°C, 2 cycles. Attenuation < 0.05 dB/km @1550 nm. |
Water Penetration | IEC 60794-1-22-F7 | 1m head for 1 hour. No leakage. |