Underground Duct Traditional Unarmored Fiber Optic Cable GYFTY B1.3

Overview:

  •  The specification covers the construction and properties of optical fiber cable.

  •  The cable shall be used directly in aerial access network.
  •  The cable generally meets the latest relevant IEC, ITU-T Recommendation or better.
  •  The single-mode fiber shall operate in 1310nm and 1550nm.
  • The cable could serve for 40 years without any significant deterioration.

Construction:

Parameter Value
Fiber Type Single-mode type ITU-T G.652D
Material Ge-doped fused silica
Mode Field Diameter 1310 nm: 9.2 ±0.4µm
Core Concentricity Error ≤ 0.5μm
Cladding Diameter 125±0.7μm
Cladding Non-Circularity ≤ 1.0%
Coating Material UV-curable acrylic
Coating Diameter ≤ 250±10μm (Colored)
Cable Model GYFTY-2/4/12/24/48/96F

 

Optical characteristics:

Parameter Value
Attenuation @ 1310 nm ≤ 0.35 dB/km
Attenuation @ 1383 nm ≤ 0.35 dB/km
Attenuation @ 1550 nm ≤ 0.20 dB/km
Attenuation @ 1625 nm ≤ 0.25 dB/km
Zero-dispersion Wavelength 1300~1324 nm
Zero-dispersion Slope ≤ 0.092 ps/(nm^2 * km)
Chromatic Dispersion Coefficient 1330 nm: ≤ 3.5 (ps/nm.km)
  1550 nm: ≤ 18 (ps/nm.km)
Cable Cut-off Wavelength (λcc) ≤ 1260 nm
Polarization Mode Dispersion ≤ 0.2 ps/(km)^0.5
Macrobend Loss (Before Cable) G.652D 30mm radius x 100 turns: ≤ 0.1 dB (at 1550 nm)
Fiber Proof-tested 0.69 GPa

Constuction 1:

Parameter Value
Cable Type GYFTY
Number of Fibers 2/F/4F/12F/24F/48F/96F
Fiber Construction Consult 3.1
Central Strength Member Material: FRP
Water Blocking Member Material: Water-Blocking Tape & Yarn
Tube Material PBT
Filling Compound Material Water-Blocking Thixotropic Gel
Filler Material PP
Rip Cord Material: Polyester
Outer Sheath Material PE
Sheath Thickness 1.5 ± 0.1 mm

Test Properties:

Test Test Method Detail Specifications Acceptance Criteria
Filling Gel Drip IEC-60794-1-2 Method E14 80°C ≤0.05 gr -
Filling Material: OIT ASTM D 3895 and GR-20 Clause 6.3.1: ≥20 min -
Cable Material Compatibility GR-20 Clause 6.3.4 85°C, 30 days -
Fiber-stripping force IEC 60793-1-32 30 mm 1.0 ≤ Fstip ≤ 9.0 N
PBT Tube Properties Tube wrapping around No cracks or delamination Per GR-20 Clause 6.3.4
Send Enquiry
Get Callback

Leave your detail here, we will call you back

We'll never share your email with anyone else.
10 digit mobile number start with 98XX

Welcome to Support Center

Support for all your needs, in one place. Sign in to get personalized help and access your registered devices, software and existing service requests.

Why create an account

Place orders quickly and easily
View orders and track your shipping status
Manage your products, and product-level contacts using Company Administration.
Generate Ticket
Stay Connected With Us
Get the latest offers, news and ideas from us
Unsubscribe
281674264