D-TECH – Fiber Technician Skill Test
For technicians, engineers, and trainees to test fiber-optic knowledge.
Section A: Fusion Splicer & Splicing Knowledge
1. Fusion Splicer – Core Alignment Technology
Which motor configuration is used in TRUE core-to-core alignment splicers?
1. 4 Motors
2. 6 Motors
3. 2 Motors
2. Cladding Alignment Splicers
Which motor configuration is most common for cladding-alignment type splicers?
1. 3 Motors
2. 4 Motors
3. 6 Motors
4. 1 Motor + 1 Fixed Clamp
3. Fusion Splicer – What Layer Is Actually Melted?
A fusion splicer welds optical fibers by aligning and melting their:
1. Coating Layer
2. Core Layer
3. Cladding Layer
4. Core + Cladding Layer
5. Coating + Cladding only
4. Common Splice Sleeve Sizes
Which splice protection sleeve sizes are commonly used in the field?
1. 40 mm
2. 45 mm
3. 60 mm
4. All of the above
5. Only 60 mm is correct
5. Why Do Splicer Batteries Get Damaged?
1. Leaving it uncharged for long time
2. Charging overnight every day
3. Using until 0% discharge
4. All of the options are wrong
5. All of the options are correct
6. Typical Electrode Life Count
What is the typical electrode life for most standard fusion splicers?
1. 2,000
2. 3,500
3. 4,500
4. 5,600
5. 10,000
Section B: Splice Loss, Cleaver & Testing
7. Causes of High Splice Loss
Which can cause high splice loss?
1. Bad cleaver angle
2. Electrode life expired
3. Fiber not cleaned
4. ARC power too high
5. Lens dirty
6. Wrong cleave length
7. Wrong fiber type mismatch
8. All are correct
9. None are correct
8. Cleaver Not Cutting Fiber – Reasons
1. Blade is dull
2. Blade not rotated
3. Fiber grip dirty
4. Fiber inserted too deep or too short
5. All are correct
6. None are correct
9. Power Meter Shows Wrong Reading Because:
1. Reference / Zero dB not set
2. Dirty connector
3. Wrong wavelength selected
4. Fiber broken
5. Loose adapter
6. All of the above
7. None of them
Section C: Fiber Cable & Connector Knowledge
10. Typical SMF Loss at 1310 nm
1. 0.25 dB/km
2. 0.35 dB/km
3. 0.18 dB/km
4. Depends on G.652 vs G.657
11. Typical SMF Loss at 1550 nm
1. 0.25 dB/km
2. 0.35 dB/km
3. 0.20 dB/km
12. Which One Is Single-Mode Fiber?
1. OS2
2. MM
3. G.651
4. G.655
13. Which Connector Gives Better Return Loss?
1. APC
2. UPC
3. XPC
Section D: OTDR, OPM & VFL
14. OTDR Is Used For:
1. Fault location
2. Total distance
3. Splice loss measurement
4. Connector loss
5. Bend loss
6. All of the above
7. None of them
15. How to Keep Optical Power Meter Safe?
1. Use and keep
2. Use and never clean
3. Clean before use
4. Clean before and after use
5. Keep without cap
16. Testing Equipment Can Be Damaged By:
1. Dust
2. Water
3. ARC power
4. VFL red light
5. Dust + Water
17. Which Device Gives Red Light?
1. OTDR
2. OPM
3. VFL
4. VFF
D-TECH Fiber Technician Skill Test
📍 Lalitpur | Itahari | Butwal
🌐 www.dtechtrading.com.np