Technical Specification for GYTC8A B1.3 Fiber Optic Cable
1. Fiber Specifications
Description:
Technical Requirements:
No
Item
Test Requirement
Test Standard
1
Core non-circularity
≤ 6%
ITU-T G.652
2
Cladding diameter
125.0 ± 0.7 μm
-
3
Core/Cladding concentricity error
≤ 0.6 μm
4
Cladding non-circularity
≤ 1.0%
5
Coating diameter
245 ± 10 μm
6
Cladding/Coating concentricity
≤ 12 μm
7
Attenuation coefficient
1310 nm: ≤ 0.35 dB/km
1550 nm: ≤ 0.21 dB/km
8
Zero dispersion slope
≤ 0.092 ps/(nm²·km)
9
Zero dispersion wavelength
1300–1324 nm
10
Polarization dispersion
≤ 0.20 ps/√km
11
Mode field diameter
1310 nm: 9.0 ± 0.4 μm
12
Cut-off wavelength
1170–1330 nm
13
Chromatic dispersion coefficient
1288–1339 nm: ≤ 3.4 ps/(nm·km)
1550 nm: ≤ 18 ps/(nm·km)
1625 nm: ≤ 22 ps/(nm·km)
2. Cable Structure
Components:
Structure Parameters:
Parameters
Tube/Fiber Color
1: Blue (Tube) / Blue (Fiber)
2: White / White
3: Yellow / Yellow
4: Green / (Missing Fiber Color)
Fiber core
12 fibers
Fibers per tube
6/12/24 fibers
Number of tubes
1/2/3 tubes
Loose tube outer diameter
1.7 mm
Central strength member
1.2 mm steel wire
Armoring material
Corrugated aluminium tape
Armoring thickness
0.15 mm aluminium + 0.05 mm coating (each side)
Galvanized steel strand wire
7 × 0.9 mm
Strand wire sheath thickness
1.5 mm
Neck dimensions (W×H)
1.6 × 2.2 mm
Outer sheath material
MDPE
Outer sheath thickness
Once videos are added, you’ll see them here as a gallery.