Fiber Specifications

  • Material: Quartz glass (Silicon Dioxide)
  • Structure:
    • Core: 9 μm (high refractive index)
    • Cladding: 125 μm (low refractive index)
    • Coating: 245 μm (protective resin)

Parameter

Requirement

Standard (if applicable)

Core non-circularity

≤ 6%

ITU-T G.652

Cladding diameter

125.0 ± 0.7 μm

-

Core/Cladding concentricity

≤ 0.6 μm

-

Cladding non-circularity

≤ 1.0%

-

Coating diameter

245 ± 10 μm

-

Cladding/Coating concentricity

≤ 12 μm

-

Attenuation coefficient

1310 nm: ≤ 0.35 dB/km

1550 nm: ≤ 0.21 dB/km

-

Zero dispersion slope

≤ 0.092 ps/(nm²·km)

-

Zero dispersion wavelength

1300–1324 nm

-

Polarization dispersion

≤ 0.20 ps/√km

-

Mode field diameter (1310 nm)

9.0 ± 0.4 μm

-

Cut-off wavelength

1170–1330 nm

-

Chromatic dispersion

1288–1339 nm: ≤ 3.4 ps/(nm·km)

1550 nm: ≤ 18 ps/(nm·km)

1625 nm: ≤ 22 ps/(nm·km)



Cable Parameters

Parameter

Value

Fibers per loose tube

6

Number of tubes

2 (total 12 fibers)

Inner sheath thickness

1.0 mm

Outer sheath thickness

1.7 mm

Aramid area

2.8 mm²

Cable diameter

12.3 mm (±5%)

Cable cross-section

106 mm²

Cable weight

105 kg/km (±10%)

4. Mechanical & Environmental Performance

  • Key Parameters:
    • RTS (Rated Tensile Strength): 4800 N
    • MAT (Maximum Allowable Tension): 1900 N
    • Static bending radius: ≥ 174 mm
    • Dynamic bending radius: ≥ 290 mm
    • Operating temperature: -40°C to +70°C
    • Installation temperature: -10°C to +40°C


5. Test Requirements

Test Type

Standard

Key Criteria

Tensile Test

IEC 60794-1-21-E1

- RTS: No break at 100% RTS.

- UOS (60% RTS): Fiber strain < 0.35%, no added attenuation.

- MAT (40% RTS): Strain < 0.05%.

Crush Test

IEC 60794-1-21-E3

≤ 0.1 dB attenuation @1550 nm under 2200 N; no residual attenuation.

Impact Test

IEC 60794-1-21-E4

450g weight, 1m height, 5 impacts. No sheath cracks or residual attenuation.

Repeated Bending

IEC 60794-1-21-E6

30 bends under 150 N load. No cracks/residual attenuation.

Torsion Test

IEC 60794-1-21-E7

±180° twist, 10 cycles. No added attenuation or sheath damage.

Temperature Cycling

IEC 60794-1-22-F1

-40°C to +65°C, 2 cycles. Attenuation < 0.05 dB/km @1550 nm.

Water Penetration

IEC 60794-1-22-F7

1m head for 1 hour. No leakage.


Customer Questions & Answers

Have a question? Ask it here!

Customer Questions & Answers

No questions asked yet. Be the first!

Login to ask a question.

Customer Reviews

No reviews yet. Be the first to review this product!

Login to leave a review.

Our Partners

D-TECH
Fujikura
Sumitomo
Tumtec
COMWAY
HSGQ
DEVISER

Secure Payment By

Connect IPS
D-TECH TRADING
281674264